PerkinElmer
check quantity

QSight Triple Quad 200 Series

Ideal for analyzing food, cannabis, and environmental samples, our robust and reliable QSight® triple quad systems consistently deliver the throughput and productivity you need in your analytical testing lab. Now we’ve added the premier model to our QSight family: the high performance 400 series. This ready-to-implement solution has the highest sensitivity and throughput the industry has ever seen and the capability to test for the most challenging, complex samples, including cannabis.

Part Number
Model Name
BC003844
QSight 400 Series
more
BC003382
QSight 200 Series
more
BC003264
QSight 100 Series
more
Buy Now

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

This workhorse system provides exceptional sensitivity for difficult matrices in commercial testing labs and the food, environmental, and cannabis industries – it’s the perfect instrument for labs that need uncompromising performance.

  • High sensitivity to meet standard and regulatory requirements
  • StayClean Source, self-cleaning design for maximum sensitivity and exceptional uptime
  • Laminar Flow Ion Guide for highly efficient field-free transmission, providing virtually no maintenance requirements
  • Dual Source technology gives you the capability to set ESI or APCI modes, with two independent probes for true multiplexing
  • Modular Simplicity 3Q software to acquire, quantify, and report with flexible data viewing options and powerful remote diagnostics.

Achieve the highest levels of performance from sample handling right through results and reporting with QSight triple quad LC/MS/MS systems.

Specifications

Model Name QSight 200 Series
Resources, Events & More
  • All

Application Note

"No Dilute” Just Shoot: Robustness of a QSight LC-ESI-MS/MS for Pesticide Residue Analysis in Wine

QSight LC/MS/MS evaluates eliminating sample preparation for trace level pesticide in wine

PDF 962 KB
A Multiclass Multiresidue Method for Analysis of Veterinary Drugs in Chicken by UHPLC/MS/MS

Veterinary drugs are used in animal production to treat diseases, prevent infection and protect growth of animals, which helps provide quality marketplace. However the uncontrolled use may cause heavy human disease so regulatory agencies around the world have established maximum residue levels (MRLs) or tolerances of veterinary drugs in foods. Drug analysis is generally challenging, due to the complexity of sample matrices and diversity of analytes from various classes of chemical properties. In this study, a fast, sensitive and selective method has been developed for analysis of 73 veterinary drugs (covering 13 different chemical classes) in chicken samples by coupling solvent extraction method with LC/MS/MS.

PDF 1 MB
A New, Sensitive Method for Lignan Metabolite Detection of Flaxseed-Fed Mice Using LC/MS/MS

A New, Sensitive Method for Lignan Metabolite Detection of Flaxseed-Fed Mice Using LC/MS/MS

PDF 1 MB
A Single Cannabis Method to Meet California Pesticide and Mycotoxin Residues Regulatory Requirements

Testing for the levels of pesticide and mycotoxins in cannabis is important to ensure consumer safety and quality control. In this work, the PerkinElmer application development team analyzed all 66 pesticides (including very hydrophobic and chlorinated pesticides typically analyzed by GC-MS/MS) and five mycotoxins spiked in cannabis flower extracts well below the action limits specified by the state of California. A LC-MS/MS instrument was used with ESI and APCI sources and a simple solvent extraction method with excellent recoveries for all analytes in acceptable range of 70-120%.

PDF 2 MB
Analysis of Acrylamide in Potato Chips by Isotopically Standard Addition UHPLC-MS/MS

Acrylamide is a probable carcinogen organic compound that is found in some foods that are cooked at elevated temperatures. It’s origins are due to the condensation of the amino acid asparagine and glucose as part of Maillard reaction. In 2002, Acrylamide was found to be present in french fries and baked bread. This compound has now also been found in some other food stuff like coffee, black olives, dried pears, and peanuts. As a result the and World Health Organizations have promptly limited its presence for human consumption.

PDF 1 MB
Analysis of Aflatoxins by UHPLC

Aflatoxin B1 is considered to be the most genotoxic of the mycotoxins, and, when ingested by cows, is converted to aflatoxin M1 which has been shown to cause liver cancer in certain animals.

PDF 1 MB
Analysis of Benzo[a]pyrene in Tobacco and Related Products

Benzo[a]pyrene (B[a]P) is a well-known carcinogenic compound found in tobacco products and tobacco smoke. The Cooperation Centre for Scientific Research Relative to Tobacco (CORESTA) has recommended a gas chromatography/ mass spectrometry (GC/MS) method to determine concentrations of B[a]P in tobacco products. In the proposed method, B[a]P is extracted from the tobacco with methanol, followed by a solid phase extraction (SPE) and subsequent concentration prior to GC/MS analysis. The CORESTA recommended method is time-consuming, especially in sample preparation procedures, and showed low sensitivity. In this application note, a simple, reliable and fast analytical method for the determination and quantification of B[a]P in tobacco products has been developed using a PerkinElmer QSight® LX50 UHPLC system, coupled to a PerkinElmer QSight 220 MS/MS detector.

PDF 582 KB
Analysis of Multi-Residue Pesticides in Rice by LC/MS/MS

Liquid chromatography tandem mass spectrometry (LC/MS/MS) has become the method of choice for pesticide analysis due to its high selectivity and sensitivity as well as its suitability for a wide range of compounds in various sample matrices. 0 In this study, a fast, sensitive and selective multi- residue method has been developed for analysis of over 200 pesticides in rice samples by coupling a modified QuEChERS extraction method with LC/MS/MS. Using time-managed- MRM in the QSight® triple quadrupole mass spectrometer, the optimum dwell time of multiple MRM transitions can be generated automatically for the targeted analytes. This not only saves time in method development but also improves data quality and analytical performance, as demonstrated in this study by the results of multi- residue pesticide analysis in rice samples.

PDF 1 MB
Analysis of Mycotoxins in Multi-Grain and Corn Cereals

Mycotoxins produced by fungi as toxic secondary metabolites, leave grains, maize and cereals particularly vulnerable. With this in mind, and considering that an estimated 25% of all crops show some signs of mycotoxin contamination, many countries have established regulatory guidelines for maximum mycotoxin limits in not only feed and grain, but also in processed food products.

PDF 991 KB
Analysis of PPCPs in Drinking Water at Low PPT Levels by Online SPE-UHPLC-MS/MS

Pharmaceutical and Personal Care Products (PPCPs) are an emerging environmental concern, and include human and veterinary prescription and over-the-counter medications, sunscreens, lotions, soaps, and insect repellants. These commonly encountered products can enter the environment through various sources, including municipal wastewater, polluting ground water, surface water, and even drinking water. The analytical challenge associated with PPCP testing is the wide variety of chemical classes/ types that are typically present at parts per trillion (ng/L) concentrations in drinking water. The automated approach described in this application note allows for significant and efficient analyte concentration, obviating the need for elaborate and time-consuming sample preparation procedures, and thus improving productivity, reducing solvent usage and laboratory waste.

PDF 2 MB
Analysis of Pork Adulterated Meat

A selective and sensitive LC/MS/MS method for fast identification and analysis of meat samples using three peptides specific for pork as biomarkers. . The optimized sample preparation procedure is easy to follow and can be used for analyzing raw, cooked and processed meat products. This method can selectively detect peptides from pork meat species at a threshold detection limit of 1% w/w (10 mg/g) in a variety of food products and thus the method can be useful for analysis of Halal food (or pork related food products) samples.

PDF 1 MB
Analysis of Water-Soluble Vitamins in Infant Formula by UHPLC-MS MS

Water-soluble vitamins (WSV), comprised primarily of the vitamin B complex, are essential ingredients in many foods, particularly in infant formulas. When analyzing fortified foods, this can be particularly challenging due to the wide range in concentration of vitamins, in keeping with daily allowances. This application note presents a LC-MS/MS method for the efficient, routine and robust chromatographic analysis of B-vitamins in infant formula. Eight water soluble vitamins over a wide concentration range were identified and quantified in under four minutes. The results showed excellent retention time repeatability and the method was able to detect vitamin B12 at 0.5 ppb, well below the expected level of ~2 ppb in infant formulas.

PDF 1 MB
Analysis of illegal dyes in Chili Spices via UHPLC-MS/MS

Since 2003 the usage of azo and non-azo dyes for food coloring has been declared as illegal by many of the food international authorities across the globe. That is because these substances such as Sudan I,II,III,IV and Rhodamine B, are potentially carcinogens and genotoxin in nature. As of now, no official methods have been published for the detection of illegal dyes however, the most used analytical technology is GC-MS or HPLC coupled with UV or MS detection.

PDF 4 MB
Detection of Fipronil and Metabolites in Eggs by LC-MS/MS

Fipronil is a broad-spectrum phenylpyrazole insecticide almost used to protect corps from insects but also to treat lice and ticks in chickens. The U.S. EPA classified fipronil as Group C, possible human carcinogen, therefore International organizations defined admissible limits for the fipronil usage which in egg is of 5 µg/L4. LC-MS/MS technology can provide a robust and reliable method to detect such a contaminant in food.

PDF 719 KB
Determination of Coumarin in Electronic Cigarette Liquids by LC/MS/MS

Coumarin (1,2-benzopyrone) occurs as a natural component in some plants, and is utilized as a flavoring ingredient in some foods, tobaccos and cosmetic products. In recent years, coumarin has been added to electronic cigarette liquid nicotine solutions as a flavoring component, producing a complex flavor profile with aromas of vanilla, almond, cherry and cinnamon. Coumarin has been found to exhibit hepatoxic effects, and has been banned by the FDA in food products, but this ban does not extend to tobacco products, such as electronic cigarettes.

This application note details a method for the analysis of coumarin in electronic cigarette liquid nicotine cartridges, utilizing PerkinElmer UHPLC system coupled to a QSight® 220 triple quadrupole mass detector with a dual ionization source.

PDF 2 MB
Determination of Mycotoxins in Cereals by LC/MS/MS with Online SPE

Mycotoxins are toxic secondary metabolites produced by fungi, and are capable of causing disease and death in both humans and animals. Sample preparation is a critical step in the successful analysis of mycotoxins in food matrices. The "dilute and shoot" approach is a quick and easy way to introduce the sample into the LC/MS/MS analysis. However, due to the complexity of food matrices, this approach will often result in irreproducible matrix effects. To overcome these problems and improve sensitivity, this application note details the use of online solid phase extraction (SPE), coupled to an LC/MS/MS system for sample enrichment.

PDF 3 MB
Determination of Polycyclic Aromatic Hydrocarbons in Seafood by UHPLC- MS/MS

Polycyclic aromatic hydrocarbons (PAHs) can contaminate foods during smoking, heating, and drying processes that allow combustion products to come into direct contact with food. They can also enter food supply chains through contaminated air and water, and accumulate in various food chains. Regulations are in place to monitor PAHs levels in foods; the EU set a stringent maximum residue limit (MRL) for BaP in muscle meat of smoked fish and smoked fishery products at 2 µg/kg.2 In this study, seafood samples were prepared using a QueChERS extraction method followed by a dispersive solid-phase extraction clean-up step. The samples were subsequently analyzed by coupling a UHPLC system with a triple quadrupole mass spectrometer.

PDF 1 MB
Determination of Sulfonamides in milk by Ultra-Performance Liquid Chromatography coupled with Tandem Mass Spectrometry (QSight™)

Antibiotics are used in dairy cattle for different treatments, but it leads to accumulation of these residues in milk. Presence of such residues in human food can be responsible for allergic reactions, toxic effects and develops resistant strains of bacteria. To protect consumers, regulatory agencies in the European Union published several official documents to regulate the control of veterinary drugs. Council Directive 96/23/EC establishes the veterinary residue control in food producing animals. In India, as per FSSAI (gazette notification dated 20th July 2018) and EIC (RMP for Aquaculture, Egg, Honey, Milk Poultry etc.) it is a mandate to do the analysis of antibiotics. EIC and FSSAI both have maximum residue limits (MRLs) for various antibiotic residues for food matrices from animals. It is essential to test milk for residues of sulfonamides considering safety and prevent exposure of consumers to veterinary drugs. In this work, we present a fast and sensitive LC-MS/MS method for the quantitative analysis of sulfonamides antibiotics in milk.

PDF 579 KB
Determination of Thirteen Beta Agonists in Pork Using UHPLC - Tandem Mass Spectrometry

Beta-adrenergic receptor agonists (ß- agonists) are synthetic drugs utilized in the treatment of conditions such as asthma in humans, and are also used as a growth-promoting agent in food-producing animals. The use of ß- agonists in food-producing livestock has been either banned or regulated across many countries owing to human health concerns.

To aid in the monitoring and detection of ß- agonists in livestock, a highly sensitive and selective analytical method has been developed, and is presented in this study. This LC/MS/MS method details the analysis of 13 ß- agonists in pork samples, and utilizes isotopically-labeled internal standards to compensate for matrix effects present in complex food matrices.

PDF 1 MB
PDF 1 MB
Direct Analysis of Glyphosate and Similar Polar Pesticides in Oatmeal by UHPLC-MS/MS

Analysis of glyphosate and similiar polar pesticides in oatmeal using the PerkinElmer QSight LCMSMS.

PDF 1 MB
Estimation of 136 pesticide residue in Black Pepper using QuEChERS extraction technique and QSight™ LC-MS/MS

It is very well known that Black pepper is a complex matrix that requires a proper extraction and clean-up method for interferences. In this study, a fast, sensitive and selective multi-residue method has been developed for analysis of over 136 pesticides in Pepper samples by coupling a modified QuEChERS extraction method with LC/MS/MS. Using time-managed- MRM in the QSight triple quadrupole mass spectrometer, the optimum dwell time of multiple MRM transitions can be generated automatically for the targeted analytes. This not only saves time in method development but also improves data quality and analytical performance of instrument.

PDF 1 MB
Estrogen Monitoring in River Water by LC/MS/MS with Online SPE

Endocrine disrupting chemicals (EDCs) have been found to have harmful effects on the health of both humans and wildlife. Of these EDCs, endogenous estrogens, such as estriol, 17ß-estriadiol, and estrone are of particular interest due to their potency/physiological activity even at very low levels. These hormones are particularly challenging to monitor, as concentrations are typically expected to be in the low ng/mL (ppb) to low pg/mL (ppt) range.

To improve sensitivity, this work utilizes the addition of on-line solid phase extraction (SPE) coupled to an LC/MS/MS system for sample enrichment and quantitation. This approach allows for significant/efficient analyte concentration, obviating the need for elaborate and time-consuming sample preparation procedures. Due to enrichment, compared to other methods, large sample volumes (= ½ liter) are no longer needed to reach part per trillion levels for estrogen monitoring in river water.

PDF 2 MB
Fast Screening 44 Illicit Drugs by UHPLC/MS/MS

Drugs of abuse, which can trigger the user’s central nervous system and induce an altered state of mind, can be divided into different types, including stimulants such as cocaine, psychoactive substances such as LSD (lysergic acid diethylamide) and marijuana, and painkillers such as morphine and heroin. The identification and determination of these drugs in different matrices is essential for forensic and toxicology studies.

This work outlines a rapid LC/MS/MS method for the separation and detection of 44 drug of abuse compounds in urine samples, and evaluates the selectivity, linearity, and sensitivity of the QSight® 220 LC/MS/MS system.

PDF 1 MB
Multi-residue Analysis of Pesticides in Animal Feed Using the QSight LC/MS/MS

Pesticides are employed in the growing of crops to prevent damage from a number of pests and fungi. When crops are grown to produce feed for livestock, there is a potential for pesticides residues to remain on the feeding stuffs, posing a risk to the livestock ingesting them. Pesticide residues are regulated by a number of governmental agencies, necessitating analytical methods that are robust enough to analyze complex matrices for a variety of analytes, while also being sensitive and selective enough to meet stringent regulations. In this application note, a fast, sensitive, and selective multi-residue method has been developed for the analysis of 94 pesticides in animal feeding stuffs, with reporting limits below European Commission MRLs of 0.01 mg/kg.

PDF 3 MB
Multi-residue Analytical Method for the Confirmation and Quantification of 500+ Pesticides in Fruit and Vegetables

Pesticides are utilized in a number of agricultural applications to prevent, destroy, or control harmful organisms or diseases, as well as protect plants or plant products during production, storage and transport. Although successful in these applications, pesticides can pose a risk when consumed by animals or humans. As such, the use of pesticides is regulated by a number of governmental agencies around the world. To monitor for pesticides in products intended for human or animal consumption, rapid multi-residue LC/MS/MS analytical methods are needed to accurately and efficiently quantify a large number of pesticides in a variety of matrices. In this application note, a fast, sensitive and selective method, utilizing a PerkinElmer QSight® 220 LC/MS/MS, is presented for the analysis of 503 pesticides in fruit and vegetable samples.

PDF 3 MB
Pesticide Residues and Illegal Additives in Wine

Both pesticides and illegal additives, if present in significant levels in wine, can pose health risk to consumers. In this study, a simple and sensitive LC-MS/MS method has been developed and applied for the determination of both pesticides and pigments in a single analytical run.

PDF 1006 KB
Pesticide in Grapes by LC-MS/MS

The Grape crop is one of the most important fruit crops consumed in the world. Grapes are consumed both as fresh and as processed products, such as wine, jam, juice, jelly, grape seed extract, raisins, vinegar and grape seed oil. A large variety of pesticides are used in grape production throughout its growing season to control pests and diseases in vineyards and to increase crop yield. Pesticide residue is a major concern for the stakeholders of the grape industry, due to more and more stringent regulations and safety standards in most countries.

PDF 1 MB
Rapid Analysis of Haloacetic Acids in Drinking Water Using UHPLC/MS/MS

Haloacetic acids (HAAs) are a class of undesired by-products resulting from the reaction of chlorinated disinfectants with natural organic matter in water, Which is known to be carcinogenic. The Japan Ministry of Health revised the inspection method for HAAs, which led to expansion of the analytical technique to include LC/MS/MS) as an alternative to the GC-MS method.

PDF 1 MB
Rapid Determination of Trace Amounts of Aniline and Its Derivatives by Direct Injection UHPLC/MS/MS

Aniline and aniline derivatives are widely used as raw materials and intermediates in the polymer, rubber, dye, pesticide and pharmaceutical industries. Unintended releases of aniliane or its derivatives into the environment pose a serious threat, with release possible during any stage of production, storage, transport, use, or disposal. Therefore, it is important and necessary to develop fast, simple, sensitive, selective and efficient methods for the determination of aniline and its derivatives in drinking and environmental waters. The aim of this study is to develop an LC/MS/MS method for rapid analysis of aniline and its derivatives in water samples by direct injection, without using time consuming sample preparation steps.

PDF 587 KB
Simultaneous Detection of Estrogenic and Progestogenic Hormones in Edible Bird's Nest

This application note presents a sensitive and reliable LC/MS/MS method using the PerkinElmer QSight

PDF 859 KB
Simultaneous Determination of Plant Growth Regulators in Bean Sprouts

A simple and sensitive method for the simultaneous determination of plant growth regulators

PDF 2 MB

Brochure

Cannabis Testing Solutions Brochure

Whether your lab is well established or just starting up, having a single-source partner who can offer turnkey solutions that meet the current regulations is essential to a successful business. For years, we’ve worked with government and contract cannabis laboratories to develop industry-leading methods, technology, and exceptional return on investment. We help drive analytical standards and commit to ensuring your laboratory has maximum uptime. Learn about our various testing methods and applications for cannabis analyses. Let us work with you to build an efficient workflow, so you can focus on growing your business and brand.

PDF 9 MB
Complete Aflatoxin M1 Testing Solutions

For third party food testing labs or producers who want to conduct aflatoxin M1 analysis in dairy products, our automated aflatoxin M1 ELISA assay and QSight LC/MS/MS aflatoxin M1 analyzer provide sensitive, accurate, and fit for purpose screening and confirmative analysis solutions that you can use out of box.

PDF 3 MB
Grain Testing Solutions Brochure

The grain industry is very complex. It’s global, diverse, and can also present analytical challenges. Today’s grain users demand more when it comes to quality, safety, and uniformity. In addition, they seek diverse products with unique characteristics.

PerkinElmer is equipped to help the grain industry in its quest to feed the world – nutritiously and economically. Our testing and analysis solutions encompass the three primary areas required for complete knowledge of grains and their derivatives – composition, functionality, and safety.

PDF 6 MB
Meat and Seafood Testing Solutions

Food testing labs like yours are constantly challenged with accurately analyzing samples quickly and efficiently - all while striving to reduce costs due to market forces. Your commitment to ensuring meat and seafood are safe for consumption, as demand increases, is an uphill battle.

Our commitment to you: to provide a range of solutions across multiple technologies, products, and services that meets or exceeds the testing needs of food processors. Our solutions offer more efficiency and increased accuracy and sensitivity for better yields in real time with minimal training.

From instrumentation and software to consumables and reagents to service and support, we are dedicated to providing you with end-to-end solutions that ease your everyday challenges of automation, throughput, service, and time to results.

PDF 6 MB
QSight Triple Quad LCMSMS 400 Series Interactive Brochure

Our QSight triple quad LC/MS/MS family has always been known for its robust and reliable performance. But now there’s something new – something better: the high performance 400 series. Our ready-to-implement solution has the highest sensitivity and throughput the industry has ever seen and the capability to test for the most challenging samples and analytes.

PDF 6 MB
QSight Triple Quadrupole LC/MS/MS

Whether you’re a lab manager or a bench chemist, you know firsthand how things are changing quickly in food and environmental analysis. And your lab needs to change to keep pace.

PDF 8 MB

Catalog

2020-2021 Chromatography Consumables Interactive Catalog

Today’s advanced and increasingly diverse chromatography laboratories are facing new challenges on a daily basis – starting from raw materials right up to the finished product. Our comprehensive portfolio of analytical solutions is designed to give you the higher accuracy, sensitivity, and ease of use your laboratory demands for examining with confidence, the purity, composition, and performance of your compounds. What’s more, a range of complementary services is available to keep your laboratory up and running, meeting the stringent requirements of a variety of environments and working practices.

Trust the consumables engineered for your instruments.

PDF 10 MB

Flyer

LC 300 & Quasar LC Columns Promotional Flyer

Whatever your separation challenge, your choice of liquid chromatography (LC) column can make all the difference. Our Quasar portfolio of LC columns combined with the improved work?ow and usability of the LC 300 system allows you to achieve rugged and reproducible results. Now, with the purchase of an LC 300 system, you can pick out a Quasar LC column free of charge. Learn more below.

PDF 903 KB
QSight Triple Quad LCMSMS Series 400 Flyer

Our QSight triple quad LC/MS/MS family has always been known for its robust and reliable performance. But now there’s something new – something better: the high performance 400 series.

PDF 3 MB

Product Note

PDF 890 KB
QSight Simplicity 3Q Software Suite

Our modular Simplicity 3Q™ software is ideal for acquiring, quantifying and reporting

PDF 1 MB
QSight Triple Quadrupole LC/MS/MS Preparing Your Lab

Lab reequirements for QSight triple quad LC/MS/MS systems, including storage, suppleis, space, electrical, power, gas supply requirements

PDF 660 KB

Regulatory Compliance Certification

QSight 110 & 120 Product Certificate

Product Certificate for the QSight 110 & 120

PDF 64 KB

Technical Note

Flow Characteristics of a Laminar Flow Interface for LC/MS/MS

Simulation using sophisticated modeling techniques has become a powerful tool for mass spectrometry

PDF 1 MB
Ion Transmission Through a Quadrupole Ion Guide

Ion Transmission Through a Quadrupole Ion Guide Under the Combined Influence of Viscous Flow and RF

PDF 1 MB