PerkinElmer
check quantity

QSight Pesticide Analyzer

Built to run hundreds of pesticides in one run, with the utmost sensitivity and efficiency, the QSight Pesticide Analyzer is the only instrument that provides 15% higher throughput than conventional systems.

Please enter valid quantity

Please login to add favorites

NULL OR EMPTY CART

Part Number
BC004902
Buy Now

You successfully added item(s) to your cart

Overview

As part of our complete pesticide solution, the QSight Pesticide Analyzer delivers all the functionality you need in a triple quad solution, plus an array of innovations you won’t find in competitive systems – all in a compact form factor that doesn’t take up valuable bench space.

Innovative technologies:

  • The StayClean technology uses hot-surface-induced desolvation (HSID), a sampling interface that never needs cleaning, resulting in 15% more uptime than conventional systems.
  • Patented Laminar Flow Ion Guide eliminates instrument drift in signal and frequent re-optimization by operating at zero potential and transporting ions by flow, ensuring the highest level of performance.
  • The QSight systems dual-source configuration can be set in ESI or APCI modes, enabling combinations such as ESI/ESI, ESI/APCI, and APCI/APCI – with the same or opposite polarities.
  • With its high-energy dynode to attract positive ions, the UniField Detector causes positive ions to collide with a high-energy dynode to form electrons that cascade into the detector, while negative ions are detected as usual for pulse counting.

From initial sample preparation and extraction to analysis and reporting, the QSight Pesticide Analyzer can deliver all the functionality you need for the most efficient high-sensitivity analyses.

Resources, Events & More

All (25)
Resource Type File Name File Format
Brochure QSight Pesticides Analyzer Brochure PDF  9 MB
Brochure QSight Triple Quadrupole LC/MS/MS PDF  8 MB
Product Note QSight LX50 UHPLC PDF  407 KB
Guide Solutions and Services For Better Results PDF  5 MB
Application Note "No Dilute” Just Shoot: Robustness of a QSight LC-ESI-MS/MS for Pesticide Residue Analysis in Wine PDF  962 KB
Application Note Analysis of Aflatoxins by UHPLC with MS/MS Detection System PDF  1 MB
Application Note Analysis of Fat-Soluble Vitamins in Methylene Chloride Using Reversed Phase UHPLC-MS/MS PDF  1 MB
Application Note Analysis of Illegal Dyes in Chili Spices via UHPLC-MS/MS PDF  4 MB
Application Note Analysis of Multi-Residue Pesticides in Rice by LC/MS/MS PDF  1 MB
Application Note Analysis of Mycotoxins in Multi-Grain and Corn Cereals PDF  989 KB
Application Note Analysis of Pesticide Residues in Cannabis Regulated by Oregon State Using LC/MS/MS PDF  1 MB
Application Note Analysis of Target Pesticide Residues in Berries with LC/MS/MS Coupled with a QuEChERS Sample Prep PDF  1 MB
Application Note Analysis of Water-Soluble Vitamin Formulations PDF  978 KB
Application Note Analysis of Water-Soluble Vitamins in Infant Formula by UHPLC-MS/MS PDF  1 MB
Application Note Detection of Estrogenic and Progestogenic Hormones in Edible Bird's Nest PDF  859 KB
Application Note Detection of Fipronil and its Metabolites in Eggs PDF  719 KB
Application Note Determination of Plant Growth Regulators in Bean Sprouts PDF  2 MB
Application Note Determination of Polycyclic Aromatic Hydrocarbons in Seafood by UHPLC- MS/MS PDF  1 MB
Application Note Determination of Sulfonamides in Honey PDF  1 MB
Application Note Determination, Confirmation and Quantitation of Multi-Class Antibiotic Residues in Milk PDF  1 MB
Application Note Direct Analysis of Glyphosate and Similar Polar Pesticides in Oatmeal by UHPLC-MS/MS PDF  1 MB
Application Note Direct Analysis of Glyphosate in Wine with No Sample Preparation PDF  745 KB
Application Note Pesticide Residues and Illegal Additives in Wine PDF  1006 KB
Application Note Rapid LC/MS/MS Analysis of Phthalates PDF  1 MB
Flyer Supra-d QuEChERS Dispersive SPE PDF  415 KB