PerkinElmer
check quantity

Avio 500 ICP-OES Cyclonic Concentric Configuration

PerkinElmer’s new Avio® 500 is a truly simultaneous, dual view, and compact ICP-OES. It utilizes a vertical plasma and is engineered to handle even the most difficult, high-matrix samples without dilution, delivering productivity, performance, and faster return on investment.

You successfully added item(s) to your cart

Part Number
Model Name
N0810010
Avio 500 Scott/Cross Flow
more
N0810011
Avio 500 Cyclonic/Concentric
more
N0810012
Avio 500 Oils
more
Buy Now

Please enter valid quantity

Please login to add favorites

NULL OR EMPTY CART

Detail Information

Avio 500's unique features include:

  • Vertical Plasma Torch Design: provides 100% matrix tolerance, minimizing sample preparation time.
  • Flat Plate Plasma Technology: delivers a more robust, stable plasma and the lowest argon consumption of any ICP (50% less than other systems).
  • Dual View: optimizes axial and radial plasma viewing to the extended linear dynamic range, measuring high and low concentrations in the same run, regardless of wavelength.
  • PlasmaShear System: offers maintenance-free, argon-free interference removal.
  • Universal Data Acquisition: enables simultaneous acquisition of all available wavelengths, with virtually no time or storage penalty.
  • Color PlasmaCam: for real-time viewing status evaluation of plasma, injector, and torch during analysis.
  • Syngistix for ICP Software: provides an intuitive, left-to-right, icon-based design; built-in, preset methods for faster, easier operation, requiring minimal training; extensive quality control options, including QC Charting; common software platform across AA, ICP, and ICP-MS.
  • Built-in Radian Remote Monitoring Service, available with Syngistix for ICP software v 4.0 or higher, provides real-time monitoring of your Avio 500 ICP-OES system’s diagnostic parameters, enhancing laboratory productivity.

And for added flexibility, the Avio 500 is available in three configurations, so that you can select the option best suited for your application(s). This configuration of the Avio 500 is equipped with Cyclonic/Concentric sample introduction to provide higher efficiency, better precision, and faster washout times. This configuration is not recommended for hydrofluoric acid applications.

 

Specifications

21 CFR Part 11 Compatible Yes
Depth 84.0 cm
Height 87.0 cm
Model Name Avio 500 Cyclonic/Concentric
Portable No
Product Brand Name Avio
Technology Type Atomic Spectroscopy
Warranty 1 Year
Weight 163.0 kg
Width 76.0 cm
Resources, Events & More
  • All

Application Note

Analysis of Impurities in Nickel with Avio 500 ICP-OES Following London Metal Exchange Guidelines

The London Metal Exchange (LME) issues specifications for a variety of purities for different metals. This work focuses on the analysis of contaminants in nickel with PerkinElmer’s Avio® 500 ICP Optical Emission Spectrometer (ICP-OES), using “Special Contract Rules for Primary Nickel”1 as a guideline for the analytes and required concentrations.

PDF 795 KB
Analysis of In-Service Oils Following ASTM D5185 with the Avio 500 ICP-OES

Globally, heavy machinery is used in construction, mining, and a variety of other areas. As the scale of the operations increase, the size, complexity, and cost of the equipment also increase, meaning that breakdowns can be costly, both in equipment repair and lost revenue. As a result, preventive maintenance is paramount. Lubricants are among the key fluids that can be tested, especially the oil used in engines. By monitoring the elemental concentration of the oil or other lubricants (hydraulics, transmission, gear), the status of that compartment can be determined.

PDF 1 MB
Analysis of Wastewaters Following US EPA 200.7 Using the Avio 500 ICP-OES

This work focuses on the analysis of wastewaters following the guidelines provided in U.S. EPA Method 200.7. The U.S. Environmental Protection Agency (EPA) developed Method 200.7 for the determination of metals and trace elements in waters and wastes by ICP-OES, with the current version being Revision 4.4.1 While the scope of this method allows it to be applied to a variety of sample types, a common application is wastewater analysis.

PDF 1 MB
Impurities in Lead with the Avio 500 ICP-OES Following London Metal Exchange Guidelines

The London Metal Exchange issues specifications for a number of different metals in several grades. This work focuses on the analysis of lead of different purities with PerkinElmer’s Avio® 500 ICP Optical Emission Spectrometer (ICP-OES), using “Special Contract Rules for Standard Lead1 ”as a guideline for the analytes and concentrations.

PDF 1 MB
Using MSF to Resolve Difficult Interferences in Metallurgical Samples with the Avio 500 ICP-OES

The analysis of trace metals in metallurgical matrices also presents a challenge for ICP-OES: spectral interferences. Many elements have a large number of emission lines (i.e. approximately 20,000 for iron), which increases the potential for spectral interferences. This effect is compounded in metallurgical samples, where the matrix element(s) are present at high levels due to the minimal dilutions used.

PDF 1 MB

Brochure

Avio 500 ICP Optical Emission Spectrometer Brochure

With a truly simultaneous system, high sensitivity and superior resolution, PerkinElmer's Avio 500

PDF 1 MB

Catalog

Atomic Spectroscopy 2018-2019 Consumables & Supplies Catalog

With instruments that are the industry standard worldwide, PerkinElmer accessories, consumables, methods and application support meet the most demanding requirements and are the preferred choice in thousands of laboratories globally.

PDF 8 MB

Guide

Atomic Spectroscopy, A Guide to Selecting the Appropriate Technique and System

This guide provides a basic overview of the most commonly used atomic spectroscopy techniques and provides the information necessary to help you select the one that best suits your specific needs and applications.

PDF 1 MB
Avio 200/500 ICP-OES Consumables and Supplies Guide

All of the consumables and supplies for the PerkinElmer Avio 200 and 500 ICP-OES instruments.

PDF 3 MB
Avio 500 ICP-OES Preparing Your Lab

The PerkinElmer Avio 500 ICP-OES instrument is a complete system

PDF 1 MB

Product Note

Syngistix Cross-Platform Atomic Spectroscopy Software

PerkinElmer's Syngistix is a workflow-based software designed to offer a harmonized user experience

PDF 1 MB

Regulatory Compliance Certification

Technical Note

PerkinElmer Avio Series Vertical Dual View ICP-OES

PerkinElmer's Avio ICP-OES series incorporates a vertically oriented plasma with complete dual-view

PDF 791 KB
PerkinElmer's ICP-OES Flat Plate Plasma System

PerkinElmer's patented Flat Plate™ plasma technology for ICP-OES provides several advantages

PDF 404 KB
PerkinElmer's ICP-OES Multicomponent Spectral Fitting

Baseline and interfering element correction (IEC) are used with ICP optical emission spectrometry

PDF 287 KB
PerkinElmer's Solid-State RF Generator for Flat Plate Plasma

PerkinElmer continues its tradition of excellence and leadership in ICP technology with RF generator

PDF 127 KB