PerkinElmer

Columns - Gas Chromatography

OF

Our wide range of capillary GC columns, for both general purpose and MS applications, are ultra-inert delivering low bleed levels coupled with tight column to column reproducibility. We also offer an extensive range of customer packed GC columns; encompassing over 300 stationary phases on upwards of 100 solid supports.

  • Products and Services

  • Resources, Events & More

Narrow your results
Product Type
  • Accessories (7)
  • Consumables (631)
Film Thickness
  • 0.02 µm (1)
  • 0.05 µm (3)
  • 0.1 µm (36)
  • 0.15 µm (29)
  • 0.18 µm (11)
  • 0.2 µm (7)
  • 0.25 µm (114)
  • 0.3 µm (3)
  • 0.33 µm (17)
  • 0.34 µm (1)
  • 0.4 µm (11)
  • 0.42 µm (13)
  • 0.5 µm (65)
  • 0.52 µm (2)
  • 0.6 µm (1)
  • 0.7 µm (2)
  • 0.83 µm (2)
  • 0.85 µm (19)
  • 1.0 µm (92)
  • 1.12 µm (1)
  • 1.27 µm (6)
  • 1.4 µm (8)
  • 1.5 µm (20)
  • 1.7 µm (3)
  • 1.8 µm (9)
  • 10.0 µm (4)
  • 2.0 µm (5)
  • 2.55 µm (13)
  • 20.0 µm (1)
  • 3.0 µm (21)
  • 4.0 µm (1)
  • 4.25 µm (4)
  • 5.0 µm (8)
  • 50.0 µm (1)
Inner Diameter
  • 0.0 mm (1)
  • 0.0 mm (2)
  • 0.1 mm (10)
  • 0.15 mm (2)
  • 0.18 mm (8)
  • 0.2 mm (79)
  • 0.25 mm (124)
  • 0.3 mm (97)
  • 0.32 mm (66)
  • 0.4 mm (43)
  • 0.45 mm (16)
  • 0.5 mm (51)
  • 0.53 mm (44)
  • 2.0 mm (14)
  • 4.0 mm (7)
Length
  • 0-10 (49)
  • 11-20 (175)
  • 21-30 (232)
  • 31-40 (4)
  • 41-50 (13)
  • 51-100 (104)
  • 101-200 (4)
Phase
  • (6%-cyanopropylphenyl)-methylpolysiloxane (17)
  • (low bleed) (1)
  • 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane (22)
  • 100% dimethyl polysiloxane (22)
  • 100% Dimethyl Polysiloxane (58)
  • 5% diphenyl / 95% dimethyl polysiloxane (35)
  • 5% diphenyl / 95% dimethyl polysiloxane (3)
  • 5% Diphenyl and 95% Dimethyl Polysiloxane (3)
  • 5% Diphenyl/95% Dimethyl Polysiloxane (10)
  • 5% Phenyl/ 95% Dimethyl Polysiloxane (1)
  • 6% cyanopropylphenyl / 94% dimethylpolysiloxane (2)
  • Alumina (3)
  • Betadextrin (1)
  • Cyanoprpylphenyl dimethyl polysiloxane (31)
  • Cycanopropylmethyl-phenylmethylpolysiloxane (13)
  • Cyclosil (1)
  • Dimethyl Polysiloxane (15)
  • Dimethyl Polysiloxane (1)
  • Diphenyl Dimethyl Polysiloxane (62)
  • phenyl group in the polymer backbone (2)
  • Phenyl Methyl Polysiloxane (46)
  • Polyethylene Glycol (56)
  • Trifluoropropylmethyl polysiloxane (34)
Product Brand Name
  • Elite (21)
  • Elite-1 (83)
  • Elite-1301 (17)
  • Elite-17 (31)
  • Elite-1701 (30)
  • Elite-17ht (High Temperature) (5)
  • Elite-17ms (9)
  • Elite-17ms+ (9)
  • Elite-1ht (3)
  • Elite-200 (34)
  • Elite-225 (13)
  • Elite-23 (2)
  • Elite-35 (10)
  • Elite-35ms (8)
  • Elite-5 (41)
  • Elite-5 Amine (1)
  • Elite-5 Anime (10)
  • Elite-502.2 (4)
  • Elite-5ht (High Temperature) (3)
  • Elite-5ms (22)
  • Elite-5MS (22)
  • Elite-608 (9)
  • Elite-624 (10)
  • Elite-Alumina (3)
  • Elite-BAC (6)
  • Elite-BAC Advantage (1)
  • Elite-Betacyclodextrin (1)
  • Elite-CL Pesticides (11)
  • Elite-Cyclosil (1)
  • Elite-FFAP (8)
  • Elite-Molesieve PLOT Phase (1)
  • Elite-MTBE (2)
  • Elite-PONA (1)
  • Elite-Q PLOT (2)
  • Elite-RX (5)
  • Elite-Siltek (1)
  • Elite-SimDist (2)
  • Elite-TPH (2)
  • Elite-VMS (10)
  • Elite-Volatiles (6)
  • Elite-WAX (29)
  • Elite-WAX ETR (25)
  • Elite-XLB (15)
  • Velocity-1 (6)
  • Velocity-5 (3)
  • Velocity-Wax (3)
Product Group
  • GC (29)
Technology
  • Capillary (187)
  • Capillary - General Purpose (139)
  • Capillary - Specialty Application (41)
  • Cartridge (48)
  • Conventional (52)
  • Conventional-Guard (2)
  • Custom Packed Columns (24)

"Columns - Gas Chromatography" 1-50 of 638 Products and Services

Sort
Per Page
PerkinElmer

Elite-5 capillary column, 30mx0.32mm, 0.25µm, with a 5m integrated guard column

Elite-5 column with both the analytical column and guard column in a continuous length of tubing; eliminating all connection associated problems. A general purpose, low polarity phase that is used for a variety of applications.
List Price : 700.00 USD
PerkinElmer

Elite-5 capillary column, 0.25µm, 30mx0.25mm, 0.25µm, with a 5m integrated guard column

Elite-5 column with both the analytical column and guard column in a continuous length of tubing; eliminating all connection associated problems. A general purpose, low polarity phase that is used for a variety of applications.
List Price : 661.00 USD
PerkinElmer

Elite-5MS II capillary column, 15mx0.25mm, 0.50µm, with a 10m integrated guard column

The Elite-5MS II columns incorporate the same phase as the Elite-5 columns but are specifically tested for low bleed performance. This configuration combines both the analytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
List Price : 488.00 USD
PerkinElmer

Elite-WAX ETR capillary column 60m x 0.53mm, 1.00µm

Elite-WAX ETR columns undergo a speical bonding process that binds the carbowax® to the polar deactivated silica. The resuting low bleed WAX column exhibits extended lifetimes even when repeatedly heated to 260oC. The Elite-WAX ETR column can be used for a wide range of compounds such as FAME's, flavor compounds, solvents, aromatocis, impurities in water and alcoholic beverages.
List Price : 1227.00 USD

Elite-BAC 1 Advantage, 30m x 0.32 mm x 1.8µm

The Elite BAC Advantage columns are designed specifically for blood alcohol analysis. Offering baseline separation of all critical compounds, including ethanol, methanol, acetone, tert-butanol, acetaldehyde, isopropanol and n-propanol, in less in 2 minutes.
List Price : 807.00 USD
PerkinElmer

Elite 1701 capillary column 30m x 0.45mm, 0.42µm

Elite-1701 columns are popular mid-polarity general purpose columns for the analysis of alcohols, oxygenates, PCB congeners, and pesticides. The mix of cyano and phenyl functionality offers a different elution order relative to less polar Elite-1 or Elite-5 columns.
List Price : 815.00 USD
PerkinElmer

Elite-5 capillary column, 20m x 0.18mm, 0.18µm

Elite-5, 5% phenyl/95% dimethyl polysiloxane, is a general purpose, low polarity phase used in a wide variety of applications. Amongst others, they are commonly used for analysis of drugs, pesticides, hydrocarbons, PCB's, essential oils, semivolatiles and solvent impurities.
List Price : 522.00 USD

Elite-VMS capillary column 60m x 0.53mm, 3.00µm

Elite VMS columns offer lower bleed, better selectivity and overall faster analysis for separating volatile organic compounds; also suitable for US EPA method 8260B. It is a highly stable polymer that provides outstanding anlaysis of volatile componds on MS detectors.
List Price : 1349.00 USD
PerkinElmer

Elite-35 capillary column, 30m x 0.45mm, 0.42µm

Elite-35 columns are general purpose, mid polarity phases ((35% phenyl)-methylpolysiloxane) commonly used for organochlorine pesticides, PDB congeners (i.e. alaclor mixes), herbicides, pharmaceuticals, sterols, phthalate resins and rosin acids.
List Price : 388.00 USD
PerkinElmer

Elite-17ms+ Capillary Column; 60m x 0.25mm, 0.25µm

The new Elite-17ms+ are general purpose, mid-polarity columns that are coated with a unique lend of dimethyl polysioxanes and diphenyl polysioxanes that is inert and selective for active environmental compounds such as PAHs, while maintaining similar selectivity and polarity as traditional Elite-17 phases.

The phase has been engineered for extremely low bleed as required by MS detectors at higher temperature as required for sensitive MS detectors.

List Price : 426.00 USD
PerkinElmer

Elite-5MS II capillary column, 15mx0.25mm, 0.25µm, with a 5m integrated guard column

The Elite-5MS II columns incorporate the same phase as the Elite-5 columns but are specifically tested for low bleed performance. This configuration combines both the analytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
List Price : 464.00 USD
PerkinElmer

25ft Carbowax-20M (Polyethylene glycol, PEG) PerkinElmer ScotColumn, Maximum Temperature: 185°C

SCOT column is a support-coated open tubular column prepared by a special process.
List Price : 706.00 USD
PerkinElmer

0.25µm, 60m x 0.32mm, Elite-WAX ETR Column (1/pack)

The Elite-WAX ETR (Extended Temperature Range) columns are manufactured with a special bonding process that binds the Carbowax® polymer to the polar deactivated silica. This results in a low bleed WAX column that exhibits extended lifetimes even when repeatedly heated to 260 °C. The bonding mechanism results in very stable polar retention that does not shift as often as observed with other WAX-type columns. This phase can be used for a wide range of compounds and matrices such as: FAMEs, flavor compounds, essential oils, solvents, aromatics, acrolein/acrylonitrile, impurities in water and alcoholic beverages.
List Price : 1234.00 USD
PerkinElmer

Elite-5MS II capillary column, 30mx0.25mm, 0.50µm, with a 5m integrated guard column

The Elite-5MS phase incorporates a phenyl group in the polymer backbone to improve thermal stability. Inert to active compounds and with extremely low bleed makes this phase ideal for sensitive GC/MS analysis. This configuration combines both the analytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
List Price : 744.00 USD

Elite-CLPesticides 2 capillary column 15m x 0.53mm, 0.42µm

Elite-CL Pesticides 2 Capillary Columns are specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide. Ideally suited for analysis following EPA methods 8081, 608 and CLP.
List Price : 566.00 USD
PerkinElmer

Elite-WAX ETR capillary column 15m x 0.53mm, 2.00µm

Elite-WAX ETR columns undergo a speical bonding process that binds the carbowax® to the polar deactivated silica. The resuting low bleed WAX column exhibits extended lifetimes even when repeatedly heated to 260oC. The Elite-WAX ETR column can be used for a wide range of compounds such as FAME's, flavor compounds, solvents, aromatocis, impurities in water and alcoholic beverages.
List Price : 512.00 USD
List Price : 7200.00 USD
PerkinElmer

Elite-5 capillary column, 60m x 0.32mm, 0.10µm

Elite-5, 5% phenyl/95% dimethyl polysiloxane, is a general purpose, low polarity phase used in a wide variety of applications. Amongst others, they are commonly used for analysis of drugs, pesticides, hydrocarbons, PCB's, essential oils, semivolatiles and solvent impurities.
List Price : 1159.00 USD
PerkinElmer

Elite 1701 capillary column 30m x 0.53mm, 1.00µm

Elite-1701 columns are popular mid-polarity general purpose columns for the analysis of alcohols, oxygenates, PCB congeners, and pesticides. The mix of cyano and phenyl functionality offers a different elution order relative to less polar Elite-1 or Elite-5 columns.
List Price : 1025.00 USD
PerkinElmer
List Price : 4510.00 USD
PerkinElmer

Elite-1 capillary column, 25m x 0.20mm, 0.33µm

Elite-1, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
List Price : 964.00 USD
PerkinElmer

Elite 502.2 capillary column 75m x 0.45mm, 2.55µm

The PerkinElmer Elite-502.2 Series of capillary columns are specifically designed for the analysis of volatiles by US EPA method 502.2. The low polarity phase is a proprietary dimethyl-diphenyl polysiloxane bonded phase.
List Price : 1430.00 USD
PerkinElmer

Elite 1301 capillary column 15m x 0.25mm, 1.00µm

The Elite-1301 columns is a general purpose low to mid polarity phase commonly used for the anlaysis of residual solvents, alcohols, oxygenates and volatile organic compounds.
List Price : 353.00 USD
PerkinElmer

Elite-XLB, Length: 20m, Inner Diameter: 0.18mm, Film Thickness: 0.18µm, Temperature Limits:30 to 340/360°C

PerkinElmer Elite-XLB (Specialty phase for GC/MS with exceptionally low bleed) Series Capillary Columns, Length: 20m, Inner Diameter: 0.18mm, Film Thickness: 0.18mm, Temperature Limits:30 to 340/360°C
List Price : 605.00 USD
PerkinElmer

Elite-XLB, Length: 60m, Inner Diameter: 0.32mm, Film Thickness: 0.25µm, Temperature Limits: 30 to 340/360°C

PerkinElmer Elite-XLB (Specialty phase for GC/MS with exceptionally low bleed) Series Capillary Columns, Length: 60m, Inner Diameter: 0.32mm, Film Thickness: 0.25mm, Temperature Limits:30 to 340/360°C
List Price : 1342.00 USD

Elite-VMS capillary column 30m x 0.45mm, 2.55µm

Elite VMS columns offer lower bleed, better selectivity and overall faster analysis for separating volatile organic compounds; also suitable for US EPA method 8260B. It is a highly stable polymer that provides outstanding anlaysis of volatile componds on MS detectors.
List Price : 834.00 USD
PerkinElmer

Elite-35 capillary column, 30m x 0.53mm, 0.50µm

Elite-35 columns are general purpose, mid polarity phases ((35% phenyl)-methylpolysiloxane) commonly used for organochlorine pesticides, PDB congeners (i.e. alaclor mixes), herbicides, pharmaceuticals, sterols, phthalate resins and rosin acids.
List Price : 732.00 USD
PerkinElmer

Elite-1MS capillary column, 15m x 0.32mm, 0.25µm

Elite-1MS, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
List Price : 390.00 USD
PerkinElmer

Elite-5MS II capillary column, 30mx0.25mm, 0.25µm, with a 10m integrated guard column

The Elite-5MS II columns incorporate the same phase as the Elite-5 columns but are specifically tested for low bleed performance. This configuration combines both the analytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
List Price : 733.00 USD
PerkinElmer

Elite-WAX ETR capillary column 15m x 0.32mm, 0.50µm

Elite-WAX ETR columns undergo a speical bonding process that binds the carbowax® to the polar deactivated silica. The resuting low bleed WAX column exhibits extended lifetimes even when repeatedly heated to 260oC. The Elite-WAX ETR column can be used for a wide range of compounds such as FAME's, flavor compounds, solvents, aromatocis, impurities in water and alcoholic beverages.
List Price : 441.00 USD
PerkinElmer

Elite-17ms+ Capillary Column; 30m x 0.32mm, 0.25µm

The new Elite-17ms+ are general purpose, mid-polarity columns that are coated with a unique lend of dimethyl polysioxanes and diphenyl polysioxanes that is inert and selective for active environmental compounds such as PAHs, while maintaining similar selectivity and polarity as traditional Elite-17 phases.

The phase has been engineered for extremely low bleed as required by MS detectors at higher temperature as required for sensitive MS detectors.

List Price : 427.00 USD
PerkinElmer

0.42µm, 30m x 0.45mm, Elite-WAX Column (1/pack)

The Elite-WAX column, a Polar Polyethylene glycol (PEG) stationary phase column, is a general purpose polar PEG phase commonly used for the analysis of polar compounds like alkenols, glycols and aldehydes.
List Price : 753.00 USD
List Price : 3330.00 USD

Elite-200 capillary column 15m x 0.25mm, 0.50µm

The Elite 200 columns contain a (trifluoropropyl)-methylpolysiloxane stationary phase that has a unique selectivity which changes eluation orders and resolves compounds that phenyl or cyano phases cannot. It is a good general purpose column for solvents, alcohols, silanes, ketones, fluorocarbons, glycols and drugs of abuse.
List Price : 407.00 USD
PerkinElmer

Elite-5MS II capillary column, 15m x 0.25mm, 0.50µm

The Elite-5MS II columns incorporate the same phase as the Elite-5 coumns but are specifically tested for low bleed performance. This configuration combines both the anlaytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
List Price : 366.00 USD
PerkinElmer

Elite-WAX ETR capillary column 30m x 0.32mm, 0.25µm

Elite-WAX ETR columns undergo a speical bonding process that binds the carbowax® to the polar deactivated silica. The resuting low bleed WAX column exhibits extended lifetimes even when repeatedly heated to 260oC. The Elite-WAX ETR column can be used for a wide range of compounds such as FAME's, flavor compounds, solvents, aromatocis, impurities in water and alcoholic beverages.
List Price : 897.00 USD
PerkinElmer

Elite-1MS capillary column, 30m x 0.32mm, 0.50µm

Elite-1MS, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
List Price : 661.00 USD

Elite-CLPesticides 2 capillary column 15m x 0.25mm, 0.20µm

Elite-CL Pesticides 2 Capillary Columns are specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide. Ideally suited for analysis following EPA methods 8081, 608 and CLP.
List Price : 622.00 USD
PerkinElmer

Elite-1 capillary column 60m x 0.32mm, 1.50µm

Elite-1, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
List Price : 1538.00 USD
PerkinElmer
List Price : 5900.00 USD
PerkinElmer

Elite-FFAP capillary column 30m x 0.45mm, 0.85µm

Elite-FFAP Columns consist of nitroterephthalic acid modified polyethylene glycol (bonded).
List Price : 780.00 USD
PerkinElmer

Elite-1 capillary column, 12m x 0.20mm, 0.33µm

Elite-1, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
List Price : 396.00 USD
PerkinElmer

Elite-624ms Capillary Column, 30m x 0.32mm, 1.80µm

The Elite-624ms incorporates a unique proprietary blend of cyanopropyl and methyl siloxanes tha results in a very inert, extremely low bleed and high thermal stability column. This column provides excellent peak shape for a wide range of compounds and is highly selective for residual solvents making it a great choice for USP<467>. These columns are manufactured for column to column reproducability, so they are well suited for validated methods.
List Price : 707.00 USD

Elite-200 capillary column 60m x 0.53mm, 1.00µm

The Elite 200 columns contain a (trifluoropropyl)-methylpolysiloxane stationary phase that has a unique selectivity which changes eluation orders and resolves compounds that phenyl or cyano phases cannot. It is a good general purpose column for solvents, alcohols, silanes, ketones, fluorocarbons, glycols and drugs of abuse.
List Price : 1247.00 USD
PerkinElmer

Elite-XLB, Length: 15m, Inner Diameter: 0.53mm, Film Thickness: 1.50µm, Temperature Limits: 30 to 320/340°C

Elite-XLB Capillary Columns are specialty phase for GC/MS with exceptionally low bleed.
List Price : 488.00 USD
PerkinElmer

Elite-5MS II capillary column, 30mx0.32mm, 0.25µm, with a 5m integrated guard column

The Elite-5MS II columns incorporate the same phase as the Elite-5 columns but are specifically tested for low bleed performance. This configuration combines both the analytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
List Price : 744.00 USD
PerkinElmer

Elite-17ht capillary column 15m x 0.32mm, 0.15µm

Elite-17ht Columns are extremely versatile, permitting the analysis pesticides, herbicides, rosin acids, phthalate esters, triglycerides, and sterols.
List Price : 439.00 USD
PerkinElmer

GC Columns Velocity-5 30 M x 0.53 mm x 1.50 µm 5% Diphenyl and 95% Dimethyl Polysiloxane

Velocity fused silica columns yield exceptional performance for general GC applications.
List Price : 461.00 USD
PerkinElmer

Elite-1ht capillary column 30m x 0.32mm, 0.10µm

Elite-1ht, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils and chemicals. Stable at higher temperatures than standard Elite-1 columns.
List Price : 1520.00 USD

"Columns - Gas Chromatography" 1-50 of 638 Products and Services

Per Page