PerkinElmer

Columns - Gas Chromatography

OF

Our wide range of capillary GC columns, for both general purpose and MS applications, are ultra-inert delivering low bleed levels coupled with tight column to column reproducibility. We also offer an extensive range of customer packed GC columns; encompassing over 300 stationary phases on upwards of 100 solid supports.

  • Products and Services

  • Resources, Events & More

Narrow your results
Product Type
  • Accessories (7)
  • Consumables (633)
Film Thickness
  • 0.02 µm (1)
  • 0.05 µm (3)
  • 0.1 µm (36)
  • 0.15 µm (29)
  • 0.18 µm (11)
  • 0.2 µm (7)
  • 0.25 µm (116)
  • 0.3 µm (3)
  • 0.33 µm (17)
  • 0.34 µm (1)
  • 0.4 µm (11)
  • 0.42 µm (13)
  • 0.5 µm (65)
  • 0.52 µm (2)
  • 0.6 µm (1)
  • 0.7 µm (2)
  • 0.83 µm (2)
  • 0.85 µm (19)
  • 1.0 µm (92)
  • 1.12 µm (1)
  • 1.27 µm (6)
  • 1.4 µm (8)
  • 1.5 µm (20)
  • 1.7 µm (3)
  • 1.8 µm (9)
  • 10.0 µm (4)
  • 2.0 µm (5)
  • 2.55 µm (13)
  • 20.0 µm (1)
  • 3.0 µm (21)
  • 4.0 µm (1)
  • 4.25 µm (4)
  • 5.0 µm (8)
  • 50.0 µm (1)
Inner Diameter
  • 0.0 mm (1)
  • 0.0 mm (2)
  • 0.1 mm (10)
  • 0.15 mm (2)
  • 0.18 mm (8)
  • 0.2 mm (79)
  • 0.25 mm (125)
  • 0.3 mm (98)
  • 0.32 mm (66)
  • 0.4 mm (43)
  • 0.45 mm (16)
  • 0.5 mm (51)
  • 0.53 mm (44)
  • 2.0 mm (14)
  • 4.0 mm (7)
Length
  • 0-10 (49)
  • 11-20 (176)
  • 21-30 (233)
  • 31-40 (4)
  • 41-50 (13)
  • 51-100 (104)
  • 101-200 (4)
Phase
  • (6%-cyanopropylphenyl)-methylpolysiloxane (17)
  • (low bleed) (1)
  • 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane (22)
  • 100% dimethyl polysiloxane (22)
  • 100% Dimethyl Polysiloxane (58)
  • 5% diphenyl / 95% dimethyl polysiloxane (35)
  • 5% diphenyl / 95% dimethyl polysiloxane (3)
  • 5% Diphenyl and 95% Dimethyl Polysiloxane (3)
  • 5% Diphenyl/95% Dimethyl Polysiloxane (10)
  • 5% Phenyl/ 95% Dimethyl Polysiloxane (1)
  • 6% cyanopropylphenyl / 94% dimethylpolysiloxane (2)
  • Alumina (3)
  • Betadextrin (1)
  • Cyanoprpylphenyl dimethyl polysiloxane (31)
  • Cycanopropylmethyl-phenylmethylpolysiloxane (13)
  • Cyclosil (1)
  • Dimethyl Polysiloxane (15)
  • Dimethyl Polysiloxane (1)
  • Diphenyl Dimethyl Polysiloxane (63)
  • phenyl group in the polymer backbone (2)
  • Phenyl Methyl Polysiloxane (46)
  • Polyethylene Glycol (56)
  • Trifluoropropylmethyl polysiloxane (34)
Product Brand Name
  • Elite (21)
  • Elite-1 (83)
  • Elite-1301 (17)
  • Elite-17 (31)
  • Elite-1701 (30)
  • Elite-17ht (High Temperature) (5)
  • Elite-17ms (9)
  • Elite-17ms+ (9)
  • Elite-1ht (3)
  • Elite-200 (34)
  • Elite-225 (13)
  • Elite-23 (2)
  • Elite-35 (10)
  • Elite-35ms (9)
  • Elite-5 (41)
  • Elite-5 Amine (1)
  • Elite-5 Anime (10)
  • Elite-502.2 (4)
  • Elite-5ht (High Temperature) (3)
  • Elite-5ms (22)
  • Elite-5MS (22)
  • Elite-608 (9)
  • Elite-624 (10)
  • Elite-Alumina (3)
  • Elite-BAC (6)
  • Elite-BAC Advantage (1)
  • Elite-Betacyclodextrin (1)
  • Elite-CL Pesticides (12)
  • Elite-Cyclosil (1)
  • Elite-FFAP (8)
  • Elite-Molesieve PLOT Phase (1)
  • Elite-MTBE (2)
  • Elite-PONA (1)
  • Elite-Q PLOT (2)
  • Elite-RX (5)
  • Elite-Siltek (1)
  • Elite-SimDist (2)
  • Elite-TPH (2)
  • Elite-VMS (10)
  • Elite-Volatiles (6)
  • Elite-WAX (29)
  • Elite-WAX ETR (25)
  • Elite-XLB (15)
  • Velocity-1 (6)
  • Velocity-5 (3)
  • Velocity-Wax (3)
Product Group
  • GC (29)
Technology
  • Capillary (187)
  • Capillary - General Purpose (139)
  • Capillary - Specialty Application (41)
  • Cartridge (48)
  • Conventional (53)
  • Conventional-Guard (2)
  • Custom Packed Columns (24)

"Columns - Gas Chromatography" 1-50 of 640 Products and Services

Sort
Per Page
List Price : 1843.00 USD
List Price : 3874.00 USD
PerkinElmer

Elite-XLB, Length: 30m, Inner Diameter: 0.53mm, Film Thickness: 1.50µm, Temperature Limits: 30 to 320/340°C

Elite-XLB Capillary Columns are specialty phase for GC/MS with exceptionally low bleed.
List Price : 861.00 USD
PerkinElmer

Elite-5MS II capillary column, 30mx0.25mm, 0.25µm, with a 10m integrated guard column

The Elite-5MS phase incorporates a phenyl group in the polymer backbone to improve thermal stability. Inert to active compounds and with extremely low bleed makes this phase ideal for sensitive GC/MS analysis. This configuration combines both the analytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
List Price : 768.00 USD
List Price : 7300.00 USD

Column Set - Models Arnel 1115/1315/1515 Analyzers

Replacement column set for the Arnel RGA – Three channel RGA; Hydrocarbons (FID), Light Gases (TCD) and He/H2 channel (TCD).
List Price : 9800.00 USD
PerkinElmer

Elite-5MS II capillary column, 15m x 0.25mm, 0.10µm

The Elite-5MS II columns incorporate the same phase as the Elite-5 coumns but are specifically tested for low bleed performance. This configuration combines both the anlaytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
List Price : 403.00 USD
PerkinElmer

Elite-1 capillary column, 105m x 0.45mm, 2.55µm

Elite-1, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
List Price : 1451.00 USD
PerkinElmer

Elite-XLB, Length: 15m, Inner Diameter: 0.53mm, Film Thickness: 1.50µm, Temperature Limits: 30 to 320/340°C

Elite-XLB Capillary Columns are specialty phase for GC/MS with exceptionally low bleed.
List Price : 488.00 USD

Elite-200 capillary column 30m x 0.53mm, 1.00µm

The Elite 200 columns contain a (trifluoropropyl)-methylpolysiloxane stationary phase that has a unique selectivity which changes eluation orders and resolves compounds that phenyl or cyano phases cannot. It is a good general purpose column for solvents, alcohols, silanes, ketones, fluorocarbons, glycols and drugs of abuse.
List Price : 1034.00 USD
PerkinElmer

Elite-WAX capillary column 15m x 0.25mm, 0.50µm

Elite-WAX column is a general purpose polar PEG phase commonly used for the analysis of polar compounds like alkenols, glycols and aldehydes. The extended operating range up to 250oC allows anlaysis of compounds that have a mwide volatility range.
List Price : 434.00 USD
PerkinElmer

Elite 1701 capillary column 20m x 0.10mm, 0.10µm

Elite-1701 columns are popular mid-polarity general purpose columns for the analysis of alcohols, oxygenates, PCB congeners, and pesticides. The mix of cyano and phenyl functionality offers a different elution order relative to less polar Elite-1 or Elite-5 columns.
List Price : 659.00 USD
PerkinElmer

Glass Empty Column, 4mm i.d., 1/4in o.d., 12 ft for AutoSystem GC/8000 Series (not on column) GC`s

Empty Columns for all your Gas Chromatography equipment come in multiple sizes and are able to fit a variety of different systems.
List Price : 600.00 USD

Elite-CLPesticides capillary column 30m x 0.32mm, 0.50µm

Elite-CL Pesticides Capillary Columns are specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide. Ideally suited for analysis following EPA methods 8081, 608 and CLP.
List Price : 988.00 USD
List Price : 1346.00 USD

Elite-CLPesticides 2 capillary column 15m x 0.25mm, 0.20µm

Elite-CL Pesticides 2 Capillary Columns are specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide. Ideally suited for analysis following EPA methods 8081, 608 and CLP.
List Price : 622.00 USD
PerkinElmer

Elite-225 capillary column, 15m x 0.25mm, 0.15µm

The Elite 225 (50%-cyanopropylmethyl)-phenylmethyl polysiloxane) is a general purpose column for the analysis of FAME's, carbohydrates, sterols and flavor compounds. It offers increased thermal stability over other "225" columns because of the unique polymer synthesis technology and proprietary siloxane deactivation.
List Price : 373.00 USD
PerkinElmer

Elite-17ht capillary column 15m x 0.25mm, 0.15µm

Elite-17ht columns are extremely versatile, permitting the analysis pesticides, herbicides, rosin acids, phthalate esters, triglycerides, and sterols.
List Price : 388.00 USD
PerkinElmer

Elite-5MS II capillary column, 60m x 0.25mm, 0.10µm

The Elite-5MS II columns incorporate the same phase as the Elite-5 coumns but are specifically tested for low bleed performance. This configuration combines both the anlaytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
List Price : 1050.00 USD
PerkinElmer

Elite-17 capillary column, 15m x 0.45mm, 0.85µm

Elite-17 columns are general purpose, mid polarity phases ((50% phenyl)-methylpolysiloxane) for the analysis of pesticides, herbicides, phalate esters, sterols and rosin acids.
List Price : 489.00 USD
PerkinElmer

Elite-1 capillary column, 30m x 0.45mm, 4.25µm

Elite-1, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
List Price : 827.00 USD
PerkinElmer

Elite 1301 capillary column 30m x 0.32mm, 1.00µm

The Elite-1301 columns is a general purpose low to mid polarity phase commonly used for the analysis of residual solvents, alcohols, oxygenates and volatile organic compounds.
List Price : 879.00 USD
PerkinElmer

Elite-XLB, Length: 60m, Inner Diameter: 0.32mm, Film Thickness: 0.25µm, Temperature Limits: 30 to 340/360°C

PerkinElmer Elite-XLB (Specialty phase for GC/MS with exceptionally low bleed) Series Capillary Columns, Length: 60m, Inner Diameter: 0.32mm, Film Thickness: 0.25mm, Temperature Limits:30 to 340/360°C
List Price : 1342.00 USD
PerkinElmer

Elite-225 capillary column, 10m x 0.18mm, 0.20µm

The Elite 225 (50%-cyanopropylmethyl)-phenylmethyl polysiloxane) is a general purpose column for the analysis of FAME's, carbohydrates, sterols and flavor compounds. It offers increased thermal stability over other "225" columns because of the unique polymer synthesis technology and proprietary siloxane deactivation.
List Price : 329.00 USD
PerkinElmer

Elite-1 capillary column 60m x 0.32mm, 1.50µm

Elite-1, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
List Price : 1538.00 USD
PerkinElmer

Elite-5 capillary column, 15m x 0.53mm, 0.50µm

Elite-5, 5% phenyl/95% dimethyl polysiloxane, is a general purpose, low polarity phase used in a wide variety of applications. Amongst others, they are commonly used for analysis of drugs, pesticides, hydrocarbons, PCB's, essential oils, semivolatiles and solvent impurities.
List Price : 608.00 USD
PerkinElmer

Elite-1 capillary column, 10m x 0.10mm, 0.10µm

Elite-1, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
List Price : 461.00 USD
PerkinElmer

Elite-Molesieve PLOT capillary column 30m x 0.53mm

Elite-Molesieve PLOT Phase Capillary Columns are for analysis of permanent gases.
List Price : 1246.00 USD
PerkinElmer

Elite-1ht capillary column 30m x 0.25mm, 0.10µm

Elite-1ht, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils and chemicals. Stable at higher temperatures than standard Elite-1 columns.
List Price : 950.00 USD
PerkinElmer

Elite 1701 capillary column 50m x 0.32mm, 1.00µm

Elite-1701 columns are popular mid-polarity general purpose columns for the analysis of alcohols, oxygenates, PCB congeners, and pesticides. The mix of cyano and phenyl functionality offers a different elution order relative to less polar Elite-1 or Elite-5 columns.
List Price : 1675.00 USD
PerkinElmer

Elite-624 capillary column, 30mx0.53mm, 3.0µm, with a 5m integrated guard column

The Elite-624 is a low to medium polarity phase. This configuration combines both the analytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
List Price : 805.00 USD
PerkinElmer
List Price : 3336.00 USD

Elite-200 capillary column 30m x 0.32mm, 0.25µm

The Elite 200 columns contain a (trifluoropropyl)-methylpolysiloxane stationary phase that has a unique selectivity which changes eluation orders and resolves compounds that phenyl or cyano phases cannot. It is a good general purpose column for solvents, alcohols, silanes, ketones, fluorocarbons, glycols and drugs of abuse.
List Price : 717.00 USD

Elite-CLPesticides 2 capillary column 30m x 0.25mm, 0.20µm

Elite-CL Pesticides 2 Capillary Columns are specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide. Ideally suited for analysis following EPA methods 8081, 608 and CLP.
List Price : 768.00 USD

Elite-CLPesticides capillary column 10m x 0.25mm, 0.25µm

Elite-CL Pesticides Capillary Columns are specially designed to overcome the coelutions and analyte breakdown typically encountered in chlorinated pesticide. Ideally suited for analysis following EPA methods 8081, 608 and CLP.
List Price : 512.00 USD
PerkinElmer

Elite-17 capillary column, 20m x 0.10mm, 0.10µm

Elite-17 columns are general purpose, mid polarity phases ((50% phenyl)-methylpolysiloxane) for the analysis of pesticides, herbicides, phalate esters, sterols and rosin acids.
List Price : 996.00 USD

GC Columns Velocity-Wax 30 M x 0.25 mm x 0.25 µm Polyethylene Glycol

Velocity fused silica columns yield exceptional performance for general GC applications.
List Price : 395.00 USD
PerkinElmer

Elite-Betacydex capillary column 30m x 0.25mm, 0.25µm

The Elite-Betacydex Columns for chiral separations that are 30 m long and have an inner diameter of 0.25 mm.
List Price : 664.00 USD

Capillary Column - 6m x 0.53 mm x 0.15 um

Former Arnel part number: 213300 Replacement capillary column for simulated distillation analysis: 6 m x 0. 53 mm x 0. 15 um. Features: stable to 430 degrees Cfilm thickness of 0.15um.
List Price : 1364.00 USD
PerkinElmer

Elite 624 capillary column 30m x 0.32mm, 1.80µm

Elite 624 columns are specially engineered low to mid polarity columns (6%-cyanopropylphenyl)- 94% dimethylpolysiloxane. They are ideal for analysing volatile pollutants and it is recommend in US EPA methods.
List Price : 755.00 USD
PerkinElmer

Elite-5ht capillary column 30m x 0.25mm, 0.10µm

Elite-5ht, 5% phenyl/95% dimethyl polysiloxane, is a general purpose, low polarity phase used in a wide variety of applications. Amongst others, they are commonly used for analysis of drugs, pesticides, hydrocarbons, PCB's, essential oils, semivolatiles and solvent impurities. Stable to higher temperatures than standard Elute-5 columns.
List Price : 760.00 USD
PerkinElmer

Elite-5MS II capillary column, 30m x 0.25mm, 0.10µm

The Elite-5MS II columns incorporate the same phase as the Elite-5 coumns but are specifically tested for low bleed performance. This configuration combines both the anlaytical column and guard column in a continuous length of tubing; eliminating all connection associated problems.
List Price : 647.00 USD
PerkinElmer

Elite-17 capillary column, 10m x 0.05mm, 0.10µm

Elite-17 columns are general purpose, mid polarity phases ((50% phenyl)-methylpolysiloxane) for the analysis of pesticides, herbicides, phalate esters, sterols and rosin acids.
List Price : 624.00 USD
PerkinElmer

Elite-1 capillary column, 60m x 0.45mm, 1.27µm

Elite-1, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
List Price : 1096.00 USD
PerkinElmer

Elite-FFAP capillary column 30m x 0.45mm, 0.85µm

Elite-FFAP Columns consist of nitroterephthalic acid modified polyethylene glycol (bonded).
List Price : 780.00 USD
PerkinElmer

Elite-WAX capillary column 60m x 0.45mm, 0.85µm

Elite-WAX column is a general purpose polar PEG phase commonly used for the analysis of polar compounds like alkenols, glycols and aldehydes. The extended operating range up to 250oC allows anlaysis of compounds that have a mwide volatility range.
List Price : 1227.00 USD
PerkinElmer

Elite-5MS capillary column 30m x 0.32mm, 0.50µm

Elite-5ms Columns are fused silica columns coated for EPA Wastewater Methods for Organic Chemical Analysis Method 611.
List Price : 988.00 USD
PerkinElmer

Elite-35ms capillary column 15m x 0.32mm, 0.25µm

Elite-35ms columns are general purpose, mid polarity phases coated with a unique blend of linked dimethyl polysiloxanes and diphenyl polysiloxanes. The resulting inert phase is selective to polar compounds such as drugs, pesticides, herbicides and PCB's whilst maintaining a similar selectivity as traditional Elite 35 phaes.
List Price : 540.00 USD
PerkinElmer

Elite-5 capillary column, 60mx0.32mm, 0.25µm, with a 5m integrated guard column

Elite-5 column with both the analytical column and guard column in a continuous length of tubing; eliminating all connection associated problems. A general purpose, low polarity phase that is used for a variety of applications.
List Price : 1159.00 USD
PerkinElmer

Elite-1MS capillary column, 15 x 0.25mm, 0.50µm

Elite-1MS, 100% dimethyl polysiloxane, columns are highly versatile, ideal for the analysis of a wide range of non-polar compounds including petrochemical samples, solvents, essential oils, chemicals and high temperature applications.
List Price : 366.00 USD

"Columns - Gas Chromatography" 1-50 of 640 Products and Services